Correction to: Poor sensitivity of "AccuPower SARS‑CoV‑2 real time RT‑PCR kit (Bioneer, South Korea)"

The Original Article was published on 14 November 2020

Correction to: Virol J (2020) 17:178 https://doi.org/10.1186/s12985-020-01445-4

After publication of our article [1] it was brought to our attention that we had not included sufficient details of the extraction method. All the samples were processed with the same RNA extraction kit "AccuPrep Viral RNA extraction kit IVD" (Bioneer, South Korea), and the same RNA extraction was used for both RT-PCR protocols. A maximum of a cycle of – 80 °C frozen/thawed was applied for some samples that could not be processed with the Bioneer RT-PCR kit within the same day that the CDC protocol. We have also tested in our lab that RNase P values do not vary after a single cycle of frozen/thawed as we do not observe an increase in RNase P Ct values when a "inconclusive" sample has to be repeated. So, we can certainly assure that no RNA degradation happens for the experimental conditions described in our study.

In addition, our Competing Interests statement was not correct. It should read "The authors declare that their affiliation institution "Universidad de Las Américas" is involved in producing a SARS-CoV-2 RT-PCR kit. However, this kit was not used in the present study."

Reference

  1. Freire-Paspuel B, Garcia-Bereguiain MA. Virol J. 2020;17:178. https://doi.org/10.1186/s12985-020-01445-4.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Miguel Angel Garcia‑Bereguiain.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Freire‑Paspuel, B., Garcia‑Bereguiain, M.A. Correction to: Poor sensitivity of "AccuPower SARS‑CoV‑2 real time RT‑PCR kit (Bioneer, South Korea)". Virol J 18, 41 (2021). https://doi.org/10.1186/s12985-021-01506-2

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/s12985-021-01506-2