Skip to main content

Recombinant adenovirus as a model to evaluate the efficiency of free chlorine disinfection in filtered water samples

Abstract

Background

In Brazil, ordinance no. 2,914/2011 of the Ministry of Health requires the absence of total coliforms and Escherichia coli (E. coli) in treated water. However it is essential that water treatment is effective against all pathogens. Disinfection in Water Treatment Plants (WTP) is commonly performed with chlorine.

Methods

The recombinant adenovirus (rAdV), which expresses green fluorescent protein (GFP) when cultivated in HEK 293A cells, was chosen as a model to evaluate the efficiency of chlorine for human adenovirus (HAdV) inactivation in filtered water samples from two WTPs: Lagoa do Peri (pH 6.9) and Morro dos Quadros (pH 6.5). Buffered demand free (BDF) water (pH 6.9 and 8.0) was used as control. The samples were previously submitted to physicochemical characterization, and bacteriological analysis. Two free chlorine concentrations and two temperatures were assayed for all samples (0.2 mg/L, 0.5 mg/L, and 15°C, and 20°C). Fluorescence microscopy (FM) was used to check viral infectivity in vitro and qPCR as a molecular method to determine viral genome copies. Real treated water samples from the WTP (at the output of WTP and the distribution network) were also evaluated for total coliforms, E. coli and HAdV.

Results

The time required to inactivate 4log10 of rAdV was less than 1 min, when analyzed by FM, except for BDF pH 8.0 (up to 2.5 min for 4log10). The pH had a significant influence on the efficiency of disinfection. The qPCR assay was not able to provide information regarding rAdV inactivation. The data were modeled (Chick-Watson), and the observed Ct values were comparable with the values reported in the literature and smaller than the values recommended by the EPA. In the treated water samples, HAdV was detected in the distribution network of the WTP Morro dos Quadros (2.75 × 103 PFU/L).

Conclusion

The Chick-Watson model proved to have adjusted well to the experimental conditions used, and it was possible to prove that the adenoviruses were rapidly inactivated in the surface water treated with chlorine and that the recombinant adenovirus expressing GFP is a good model for this evaluation.

Background

Currently, enteric viruses are considered to be the main etiological agents of waterborne diseases, accounting for 30-90% of gastroenteritis worldwide [1]. Enteric viruses are frequently aggregated in the environment [2], and due to the small size of the particles (0.5 – 1.0 μm), they are not efficiently retained in the filtration stage at Water Treatment Plants (WTPs) [3]. Disinfection is therefore critical for reducing the infectious virus concentrations in source water.

According to the guidance manual published in 1991 by the Environmental Protection Agency of the United States (US EPA), a 4log10 (99.99%) removal or inactivation of enteric viruses by filtration and/or disinfection is recommended. The EPA also recommends values for the contact time - Ct (disinfectant concentration (mg/L) x time (min)) of 4, 6 and 8 to achieve inactivation of 2log10, 3log10 and 4log10, respectively, using free chlorine [4]. However, the values established in this manual were based on studies with hepatitis A in buffered demand free water at 5°C. As the water quality can significantly affect the effectiveness of the disinfection by free chlorine [5], it is unclear whether these recommended Ct values are sufficient to inactivate other viral pathogens in different water matrices.

Enteric viruses are generally more resistant to environmental conditions and conventional water treatment using chlorination and filtration than enteropathogenic bacteria, and there is no potential for replication in the environment because the viruses are obligatory intracellular parasites. Although virus degradation is expected to occur, the amount of virus that remains is more meaningful than the amount of remaining bacteria that can re-grow after being excreted. There have been virus-related outbreaks with the consumption of water in compliance with bacterial standards [6].

The human adenovirus (HAdV) belongs to the Adenoviridae family, genus Mastadenovirus, comprising 57 serotypes [7]. HAdV has been indicated as a potential marker of human fecal contamination in water [6]. The current contaminant candidate list of the aquatic environment (CCL3) considers the adenovirus as a high priority emerging contaminant present in drinking water and a candidate contamination marker of the aquatic environment [8].

HAdV has been extensively detected in environmental matrices. In 2005, Choi and Jiang [9] found that 16% of the river samples in California, USA were positive for HAdV (102 - 104 gc/L). Albinana-Gimenez et al. in 2009 [10] described that 90% of the river water samples in Barcelona, Spain were HAdV positive (101 - 104 gc/L). Dong et al. in 2010 [11] detected HAdV in 100% of the sewage samples (1.87 × 103 - 4.6 × 106 gc/L) and in 83.33% of the recreational water samples (1.7 × 101 – 1.19 × 103 gc/L) in New Zealand. Win-Jones et al., in 2011 [12] found that 60.6% of the European recreational and fresh water samples were positive for HAdV, with a mean value of 3.260 × 103 gc/L. In 2012, Fongaro et al. [13] described an HAdV presence in 96% of the samples collected in the Peri Lagoon, Brazil (1.73 × 106 - 2.41 × 108 gc/L) and Garcia et al. (2012) [14] described a presence of HAdV in 100% of the river water samples in Brazil, with an average of 107 gc/L. In the same year, Ye et al. [15] described 100% HAdV positive for river and drinking water samples in Wuhan, China (102 - 104 gc/L).

Several studies have evaluated the inactivation efficiency of HAdV by free chlorine in buffer [3,16,17] in waters from rivers and lakes [5], groundwater [3], seawater [18] and sewage [19]. However, the methods chosen to evaluate the HAdV infectivity are often time-consuming. The plaque assay has long been considered a standard method, although it can require 5 to 12 days to achieve results [5,17-19]. Other methods are based on genome detection, such as PCR or the observation of a cytopathic effect.

As an alternative, recombinant adenoviruses (rAdV) can be used as a viral model to study the water disinfection procedures. rAdV are defective in their replication, as they lack the early gene, E1, which is involved in viral gene transcription, DNA replication, and the inhibition of host cell apoptosis [20]. Thus, rAdV replication is weakened in this condition, unless the replication occurs in permissive cell lines that express the E1 gene products, such as the Human Embryonic Kidney (HEK) 293A cells [21]. rAdV replication can, therefore, be directly monitored by fluorescence methods, based on the expression of the green fluorescent protein (GFP) that is encoded by a gene incorporated into the viral DNA. HEK 293A cells infected with rAdV provide a novel reporter for viral infectivity assays, enabling the use of rapid (24 h) and quantitative methods of monitoring GFP expression in individual cells, such as fluorescence microscopy.

In this context, the goal of the present study was to evaluate the viral inactivation in water collected from two Water Treatment Plants after the filtration (non-disinfected) by subsequent free chlorine addition, using the recombinant adenovirus as a model. Buffered demand free (BDF) water was used as the control. This study also evaluates the treated water quality throughout the water distribution network in relation to the concentration of human adenovirus and total coliforms.

Results

Water quality of the Lagoa do Peri (LP) and Morro dos Quadros (MQ) water treatment plants

The physicochemical parameters of the source waters used in the disinfection experiments are shown in Table 1.

Table 1 Physicochemical parameters of the water samples

Disinfection assays

To determine the influence of the seeded virus stocks on the chlorine demand, the free chlorine decay was analyzed in the water samples with and without the seeding purified virus stock. No significant differences were found between the two conditions (P > 0.05) (not shown). In general, the concentrations remained constant during the analysis period, showing no significant decay (P > 0.05). The rates of the free chlorine decay, although very low, were used to model the exponential regression by the Chick-Watson model.

No significant log reduction of the viral stock was observed over time for all of the analyzed matrices (P > 0.05) for the positive control (not shown). Thus, any log reduction observed in the experiments using the free chlorine was due to the germicidal efficacy of this compound and not to the exposure of the virus to the experimental conditions (e.g., time, matrix composition, and temperature).

The titer of the purified virus stock was 9 × 108 FFU/mL, enough to observe a 4log10 reduction using fluorescence microscopy because the detection limit for this technique was 8.5 × 101 FFU/mL (the virus stock used to determine the detection limit had a titer of 8.5 × 107 FFU/mL). Using this virus stock, the lowest ten-fold dilution that enabled us to count infected fluorescent cells was the 10−6 dilution and, for this reason, this dilution was considered the detection limit for this viral titer and for this amount of inoculum (8.5/0.1 mL = 8.5 × 101 FFU/mL). Figure 1 shows the fluorescent pattern of the HEK 293A cells infected with rAdV under fluorescence microscopy.

Figure 1
figure 1

HEK 293A cells infected with rAdV by fluorescence microscopy and light microscopy. Viral concentration of 8.3 × 105 FFU/mL (A), 8.3 × 104 FFU/mL (B), 8.3 × 103 FFU/mL (C), and cell control (D) by fluorescence microscopy, 40x magnification. Cells infected with 8.2 × 105 FFU/mL by light microscopy (E), fluorescence microscopy (F) and merged (G), and an example of 3 green fluorescent cells considered to determine the viral titer (H), 400x magnification.

The free chlorine rAdV disinfection was performed in duplicate, with 0.2 mg/L and 0.5 mg/L free chlorine in the LP and MQ samples and in the BDF buffer pH 6.9 and 8.0, at 15°C and 20°C. A four-log inactivation was attempted for all of the experiments. The time required to inactivate 4log10 rAdV was less than 1 min for both concentrations (0.2 mg/L and 0.5 mg/L) of free chlorine when analyzed by fluorescence microscopy (Figures 2, 3 and 4), with the exception of the BDF buffer at pH 8.0, which showed the slowest decay of approximately 2.5 min with 0.5 mg/L of free chlorine to decay 4log10 and 5 min with 0.2 mg/L of free chlorine to achieve the same decay (Figure 5).

Figure 2
figure 2

Inactivation curves of rAdV in BDF buffer pH 6.9. Temperature of 20°C, free chlorine concentration of 0.2 mg/L and 0.5 mg/L by qPCR and fluorescence microscopy (FM) assays.

Figure 3
figure 3

Inactivation curves of rAdV in Lagoa do Peri water treatment plant. Sample pH 6.9, temperature of 20°C, free chlorine concentration of 0.2 mg/L and 0.5 mg/L by qPCR and fluorescence microscopy (FM) assays.

Figure 4
figure 4

Inactivation curves of rAdV in Morro dos Quadros water treatment plant. Sample pH 6.5, temperature of 20°C, free chlorine concentration of 0.2 mg/L and 0.5 mg/L by qPCR and fluorescence microscopy (FM) assays.

Figure 5
figure 5

Inactivation curves of rAdV in BDF buffer pH 8.0. Temperature of 20°C, free chlorine concentration of 0.2 mg/L and 0.5 mg/L by qPCR and fluorescence microscopy (FM) assays.

The MQ water sample (pH 6.5) showed the highest disinfection rate, requiring 7 s to reduce 4log10 with 0.5 mg/L and approximately 20 s with 0.2 mg/L at 20°C (Figure 4). In general, the viral inactivation was higher in MQ (pH 6.5) (Figure 4), followed by LP (pH 6.9), the BDF buffer pH 6.9 (Figures 3 and 2) and finally the BDF buffer pH 8.0 (Figure 5). When the influence of temperature was analyzed, no significant difference was found between the experiments performed at 20°C and 15°C (P > 0.05); therefore, only the results obtained at 20°C were expressed graphically. No significant variation of the logarithmic reduction was observed for all experimental conditions when analyzed by qPCR (P > 0.05) (Figures 2, 3, 4 and 5).

No significant difference was found between LP and MQ when compared with the BDF buffer at pH 6.9 (P > 0.05). The experiments conducted with 10 mL and 40 mL also showed no significant difference (P > 0.05).

Kinetic modeling

The Chick-Watson (CW) model was used to predict the free-chlorine inactivation kinetics of rAdV for each experimental condition. Table 2 lists the parameters estimated by the CW model analysis: k’ (rate of free chlorine decay), k (rate of viral inactivation) and R2 (Ln (N/N0) observed x Ln (N/N0) of the Chick-Watson model).

Table 2 Parameters estimated by Chick-Watson model analysis

The Ct values (mg/L x min) predicted for the viral inactivation are shown in Table 3. As seen in Figures 2, 3, 4 and 5, the viral inactivation followed the same pattern, with lower Ct values of the 4log10 inactivation for MQ (0.067 and 0.101), followed by LP (0.14), the BDF buffer pH 6.9 (0.187) and finally the BDF buffer pH 8.0 (1.87 Ct value; Table 3).

Table 3 Ct values for rAdV inactivation by free chlorine determined by Chick-Watson model

Treated water quality

The t-MQ, t-LP, n-MQ and n-LP water samples were analyzed for the total coliforms and Escherichia coli (E. coli), the free chlorine concentration (mg/L), and the HAdV viability. The average recovery of the organic flocculation for the virus concentration was 6.4%. The range of the free chlorine concentration was from 0.57 to 4.0 mg/L and is within the standard required by the MH Ordinance 2.914/2011, which defines a minimum of 0.2 mg/L and a maximum of 5.0 mg/L [22]. None of the samples were positive for both the total coliforms and E. coli, with values lower than 1.1 MPN/100 mL (sensitivity limit). Among the tested samples, t-MQ showed contamination with 2.75 × 103 PFU/L infectious HAdV (value corrected by recovery), and at this point, the measured free chlorine concentration was 0.57 mg/L. None of the other samples were positive for HAdV, with values lower than 1 × 103 PFU/L (sensitivity limit).

Discussion

The application of recombinant adenovirus provides a versatile system for therapeutic applications and gene expression studies, including gene transfer in vitro, gene therapy and vaccine therapy [20]. Despite this well-established use, we describe herein a novel application of rAdV in the environmental virology field, especially in disinfection assessment studies. The current study shows, for the first time, the efficiency of free chlorine disinfection of rAdV in water samples undergoing treatment for human consumption. The temperatures of 15°C and 20°C mimic the temperature range of the natural waters in south Brazil during the winter and summer seasons [23], respectively, and the pH conditions, which were not modified. We believe that it is very important to select temperatures that assess the real conditions that occur in the real environment. Comparison techniques based on genome detection (qPCR) and infectivity (cell culture) are also important because risk assessment studies based on genomic copy detection are encouraged [24-28], and other studies have reported that free chlorine can damage genetic material [29,30].

The use of rAdV proved to be economical, convenient and fast for several reasons: it does not require the use of primary and secondary antibodies; it decreases the possibility of overestimating the viral titers due to non-specific binding; it avoids cell loss during the washing stages commonly performed in immunodetection techniques; and it is faster (24 h) than the conventional plaque assay method (7 to 10 days), described by Cromeans et al. (2008) [31].

Regarding the GFP fluorescence stability in chlorine solutions, according to Mazzola et al. (2006) [32], who evaluated the GFP stability in chlorinated water and buffered solutions, the main conclusion was that GFP is a suitable fluorescent marker for monitoring disinfection effectiveness. They observed that, with constantly stirred solutions, the GFP fluorescence decreased abruptly after contact with chlorine in concentrations greater than 150 ppm, and the GFP fluorescence intensity was reduced by 42% in the initial 30 s of contact with a 70 ppm phosphate buffered chlorinated solution. Webb et al. (2001) [33] exposed Aureobasidium pullulans cells expressing GFP to chlorinated solutions (25–150 ppm) and observed that the loss of GFP fluorescence was highly correlated with a decrease of the number of viable cells. Casey and Nguyen (1995) [34] exposed Escherichia coli cells also expressing GFP and observed the same result as Webb et al. (2001). In the present study, the chlorine concentrations employed were 0.2 ppm and 0.5 ppm, much lower than the values described above. Therefore, we can conclude that the GFP fluorescence itself was not affected by this low concentration of applied chlorine, and the lack of fluorescence is certainly due to a lack of rAdV replication. This phenomenon was also proven by the same effect of the chlorine on viral disinfection using non-recombinant human adenovirus, which was previously described in the literature [3,5,17].

Viral purification is essential for the experiments of disinfection by free chlorine because viral suspensions contain considerable amounts of organic matter that consumes free chlorine, preventing its virucidal and bactericidal action [18]. This work was the first to use chromatography as a method of purification and proved to be comparable to studies using other forms of purification, with comparable and adequate Ct values [5,17] because the concentrations of disinfectant did not vary significantly in the presence of the purified virus stock (P > 0.05).

No significant difference in the disinfection efficiency was observed (P > 0.05) between the tested temperatures (15°C and 20°C). However, the pH variation exerted a great influence on the disinfection efficiency: the Ct for the 4log10 disinfection at BDF pH 8.0 (1.87) was 10 times greater than the Ct at BDF pH 6.9 (0.187). This result is due to residual free chlorine in both pHs; at pH 8.0 there is approximately 25% HOCl and 75% of the hypochlorite ion (HCl+), and at pH 6.9, approximately 80% is HOCl, and 20% is HCl+. According to AWWA (2006) [35], the germicidal efficiency of HOCl is approximately 100 times greater than HCl+, which explains the observed results; therefore, the pH of the water can cause a variability in the disinfection efficiency.

Nevertheless, fresh water submitted to water treatment is constantly influenced by geological features. It is well known that the levels of chemicals in soils reflect the levels at the source rock, except in cases with anthropogenic influence [36,37], and the geology has a great influence on the chemical characteristics of the soil and surface water [38]. Moreover, it has been demonstrated that the pH values can vary in different water bodies, such as rivers, water reservoirs or estuaries, depending on the season [39-41] and the daily basis [40,42] and spatially (variation throughout the water layer or sampling sites) [42,43]. Furthermore, air pollutants, such as carbon dioxide (CO2), have a great influence on the pH of water because air pollutants can enter the water through biological metabolism involving organic carbon and through equilibrium with the atmosphere. Once in the water, CO2 reacts and forms bicarbonate (HCO3 ) and carbonate (CO3 2−), decreasing the pH. Therefore, more air pollution results in more CO2 in the water and higher water acidity [44]. Some other factors can affect the disinfection efficiency, such as antioxidants from commercial hygiene products, which reduce hypochlorite to chloride ions and decrease the free chlorine available for disinfection [45,46]. In addition, it is well known that the temperature range can influence the pH, as well as the CO2 solubility and may vary on a daily basis [47]. Altogether, these factors can affect the pH and change the disinfection dynamics. Thus, it is essential to carefully control the pH in water treatment plants throughout the process, especially before the addition of chlorine, due to its great influence on the disinfection performance.

It is possible to observe that the inactivation curves for all of the experimental conditions, except for the BDF pH 8.0, were characterized by two phases: an initial phase in which the inactivation occurred rapidly (approximately 2log10 in 2 seconds), followed by a phase with a lower rate of inactivation, which may be designated the “tailing phase.” Page et al. (2009) [16] described that the loss of disinfection efficiency observed during the tailing phase is most likely due to the rapid change of specific chemical moieties on the viral structure that preferentially react with HOCl. Thus, some authors propose that the HOCl-mediated transformation of proteins, which is due to the high reactivity with proteins and their abundance in biological systems, plays a key role in the loss of the biological function of this form of the free residual chlorine, leading to the formation of the tailing phase [48]. As the main feature, adenovirus capsids are composed of proteins (fibers, pentons and hexons) that are physically exposed to the disinfectant. These proteins contain functional groups, such as amines and thiols, that react with free chlorine, leading to a loss of the biological function of the disinfectant [49].

The inactivation curve in the BDF pH 8.0 experiments may be associated with damage involving secondary oxidizing agents [16]. In addition, at this pH, the HOCl concentration is approximately 25% [35], making the disinfection slower with no biphasic behavior observed.

The qPCR assay has already proven to be fast and specific for the detection and quantification of rAdV genomes. However, this technique does not provide sufficient information about inactivated viruses compared with the fluorescence microscopy technique after cell culture. The time necessary for the assays was determined by the disinfection achievement. Therefore, once the 4log10 of disinfection was achieved, the experiment was considered concluded, although the viral genomic copies did not show a significant log reduction. In fact, some studies had performed viral disinfection studies employing PCR, and some studies indeed showed a reduction of the viral copies. Nevertheless, they observed the same profile: the genome integrity decreased more slowly than the viral viability [18,19,30,50-54]. Although some studies have reported that free chlorine can damage the viral genetic material [30] by interacting with the amine group of nucleotides [29], it is suggested that the extent of DNA damage caused by free chlorine is not sufficient to detect viral inactivation by the qPCR technique, which often results in very small amplicons [55]. Even with qualitative PCR using primer sets that generate greater amplicons (400 bp to 1,215 bp), the genome integrity is not correlated with the viability of HAdV because the PCR products are generated even when higher concentrations of chlorine are used [30]. This result suggests that the ability of free chlorine to cause damage in the viral genome is limited [30], and viruses with lesions in the capsid proteins caused by chlorine may still contain their genomes that are protected from the inactivation procedures. Thus, the viral nucleic acids detected by PCR or qPCR can be derived from infective and non-infective damaged viruses and from free nucleic acids from lysed viruses, and the results obtained by cell culture, when possible, are more representative of the actual health risk. Therefore, risk assessment studies based on genomic copy detection are inadequate, overestimating the actual risk of consuming drinking water treated with chlorine.

The absence of viable HAdV in the output of both WTPs and the presence of infectious virus in the distribution network suggest that the water treatment is efficient for the inactivation of HAdV; however, the water is re-contaminated during its distribution and/or storage. Thus, low concentrations of residual free chlorine throughout the water distribution system are not sufficient to inactivate high viral loads that are accidentally re-introduced after the water treatment process [3].

It is postulated that biofilms in the drinking water distribution networks may play a role in the accumulation, protection and dissemination of pathogens [56]. The formation of biofilms has been described to provide bacteria much greater resistance to free chlorine, and it has also been shown that viruses can adsorb into biofilms [57]. The detection of viable HAdV in the distribution network may be due to viral aggregation and adsorption by particles, which have previously been reported as increasing the resistance to chlorine and the environment [2,3] or adsorption into biofilms, also protecting them from the action of the free chlorine disinfectant.

As described in the literature, the human adenovirus is rapidly inactivated by free chlorine. However, it is difficult to make a direct comparison of the Ct values due to variations in the experimental conditions, especially the technique used for the viral purification [5]. Thurston-Enriquez et al. (2003) [3], Kahler et al. (2010) [5], and Cromeans et al. (2010) [17] reported Ct values similar to those observed in the present study, except for BDF at pH 8.0, which was reported previously as 0.24 to inactivate 4log10 [3], in contrast to the 1.87 value observed in this study. However, the Ct value of 0.24 that was described by Thurston-Enriquez et al. (2003) [3] was calculated by the model, whereas the Ct observed in the experiment (not modeled) was 36.09 for the 4log10 reduction. Taken together, these data indicate the high susceptibility of the human adenovirus to free chlorine. Because the present work employed rAdV, and the Ct values reported in the literature for HAdV are comparable, this result confirms the applicability of rAdV as a model for HAdV for studies of free chlorine disinfection and discards the need to perform all experiments with HAdV in parallel in this study. By comparing the Ct values recommended by the EPA [4] with those predicted by modeling, the values are lower than those recommended in all of the experimental conditions, providing a margin of safety for free chlorine water treatment in terms of the human adenovirus.

The Chick-Watson model was chosen as it best fits the reactors in the batch mode or ideal piston, in which the longitudinal dispersion is equal to zero [58]. As the experiments were performed in 10 or 40 mL, the longitudinal dispersion is disregarded. The values of k (inactivation constant rate) calculated by the Chick-Watson model are in agreement with what was observed: the inactivation was faster in MQ, followed by LP/BDF pH 6.9 and finally BDF pH 8.0 (Table 2 and Figures 2, 3, 4 and 5) because the k value is directly proportional to the inactivation rate.

The constants of the Chick-Watson model described herein (k, k’) were determined by conducting bench experiments. These constants are considered characteristic for the rAdV inactivation kinetics, the specific conditions of the pH and temperature, and the composition of the environmental matrices. Therefore, these constants can be used to calculate the Ct at other chlorine concentrations, without the need to perform additional bench experiments.

Conclusion

The concentrations of chlorine (0.2 mg/L and 0.5 mg/L) applied to the filtered surface water were effective in inactivating the recombinant adenovirus, which proved to be highly susceptible to chlorine under the conditions studied. The factor that most influenced the disinfection was the pH. The rAdV proved to be a suitable model for this assessment, comparable to the results described in the literature in relation to the non-recombinant human adenovirus. Additionally, the matrix composition did not seem to interfere with the disinfection efficiency. The detection of viable HAdV in the supply network suggests a re-contamination of the water, and the residual chlorine concentration may not be sufficient to inactivate the viruses that have been introduced after the water treatment process.

Materials and methods

Virus and cell line

The recombinant human adenovirus (rAdV) serotype 5 was propagated in HEK 293A cells, which were maintained in growth medium composed of Dulbecco’s Modified Eagle Medium (DMEM 1X), supplemented with 10% of fetal bovine serum (FBS) and 1% of HEPES. Five hundred milliliters of the virus stock was produced by a host cell infection using a multiplicity of infection (MOI) of 5. After 24 h of incubation, the flasks were freeze-thawed three times and centrifuged at 3,500 × g for 15 min. The supernatant was recovered and submitted to viral purification using the Vivapure® AdenoPack Stedin Sartorius™ 500 commercial kit.

Briefly, 500 mL of the infected cell supernatant was treated with 12.5 U.mL−1 of Benzonase® for 30 min at 37°C, with the aim of degrading the nucleic acids from the cells and the viral particles. After adding Loading Buffer™, this suspension was pumped at 10 mL/min through the chromatography filter and, based on the specific surface viral characteristics, the virus particles were specifically retained. The Washing Buffer™ was then used to remove the contaminants, and 10 mL of the Elution Buffer™ at 1 mL/min was used to elute the viruses from the filter. The eluate was reconcentrated by Vivaspin 20 by centrifugation at 6,000 × g for 15 min, or until the virus stock could be concentrated at approximately 1 mL. With the addition of 9 mL of phosphate-buffered saline (PBS), the purified virus stock was stored at −80°C in aliquots of 0.1 mL.

The human adenovirus 2 (HAdV2) was propagated in a continuous line of A549 cells (permissive cells derived from human lung carcinoma cells, European Collection of Cell Cultures). These cells were kindly donated by Dr. Rosina Gironès from the University of Barcelona, Spain. The A549 cells were propagated in growth medium, consisting of Dulbecco’s Modified Eagle Medium high glucose (DMEM ↑G 1X), supplemented with 5% of fetal bovine serum (FBS) and 1 mM of sodium pyruvate.

Treated water quality – collection and concentration

These samples were collected to evaluate the quality of the treated water in relation to the HAdV viability, the total coliforms and the E. coli. For this evaluation, 4 L of treated water was collected from the Lagoa do Peri (WTP LP) and Morro dos Quadros (WTP MQ) Water Treatment Plants, henceforth referred to as the “treated LP” (t-LP) and “treated MQ” (t-MQ), respectively. Another 4 L water samples were collected from one point in each of the two distribution network supplied by its respective WTP. The samples from the distribution network were collected from a tap at the Universidade Federal de Santa Catarina that was supplied by the WTP MQ and from a residence supplied by the WTP LP, here designated as “network LP” (n-LP) and “network MQ” (n-MQ). All four of the samples were previously treated with 10% sodium thiosulfate and submitted to an analysis of the total coliforms and E. coli and then subjected to the flocculation method for virus concentration, as described by Calgua et al. 2013 [59].

The samples were placed in 2 liter-glass beakers (2 beakers per sample), 1.5 g/L of sea salts (SeaSalts - Sigma) were added, and the pH was adjusted to 3.5 with a 1 N HCl solution. A suspension of HAdV (1 × 107 PFU) was added to one of the beakers to assess the viral recovery. Twenty milliliters of skimmed milk solution at pH 3.5 (Pre-flocculated Skimmed Milk, 0.1% - Difco) prepared in artificial seawater (1.5 g/L SeaSalts - Sigma) was added to each beaker. Over a period of 8 h of stirring, the flocks of the acid milk provide a proper surface for viral adsorption and, after 8 h of resting these flocks settle. The supernatant was aspirated, the precipitate was centrifuged at 7000 × g for 30 min at 4°C, and the pellet was resuspended in 10 mL of phosphate buffer (NaH2PO4, Na2HPO4, 0.2 M, 1:2 v/v, pH 7.5). The final concentrate was immediately submitted to the plaque assay.

Plaque assay

The t-LP, t-MQ, n-LP and n-MQ concentrated samples were treated with 1% PSA and inoculated in triplicate in a non-cytotoxic dilution in A549 cells for the plaque assay, as described by Cromeans et al. 2008 [31], with minor modifications (using 0.6% Bacto-agar). Afterwards, the cells were stained with 20% Gram’s crystal violet, the plaques were counted, and the results were expressed in Plaque Forming Units per liter (PFU/L). The theoretical limit of sensitivity limit of this method is 1 × 103 PFU/L.

Disinfection assays

Tested waters

Water samples undergoing treatment were obtained at the Lagoa do Peri Water Treatment Plant (LP) located at Peri Lagoon, city of Florianópolis and the Morro dos Quadros Water Treatment Plant (MQ), located in Palhoça city. Both cities are located in Southern Brazil in the State of Santa Catarina. The water samples were collected after regular treatment (a filtration step) and immediately prior to chemical disinfection. Ten liters of each sample was collected, aliquoted in 500 mL, and stored at −20°C.

Experiments were also conducted with buffered demand free (BDF) water, prepared by dissolving 0.54 g of Na2HPO4 (anhydrous) and 0.88 g of KH2PO4 (anhydrous) per liter of deionized, chlorine demand-free water. The pH was adjusted to 8.0 and 6.9 by adding 1 M KH2PO4. The BDF water was stored in chlorine-demand-free bottles at 4°C until use.

Physicochemical parameters and fecal contamination analysis

Using a multiparameter probe (YSI-85), the LP and MQ samples were submitted to physicochemical analysis in situ to determine the temperature, conductivity, and pH. In the laboratory, the samples were analyzed for turbidity, nitrite (NO2 ) [60], nitrate (NO3 ) [61], and ammonia (NH3) [62]. The nutrients were measured in the filtered water samples using a Millipore AP40–47 mm glass fiber.

A fecal contamination analysis was performed using a commercial Aquatest Coli – ONPG MUG Laborclin. One hundred milliliters of the MQ, LP, t-LP, t-MQ, n-LP and n-MQ samples was analyzed, aliquoted in 5 tubes of 20 mL and incubated for 24 h at 35 ± 2°C. The number of positive tubes was counted, and the results were expressed as the Most Probable Number (MPN) of total coliforms per 100 mL. The sensitivity limit of this technique is 1.1 MPN/100 mL.

Reagents and glassware treatments

The glassware was made chlorine demand-free, as previously described [3]. The beakers were soaked overnight in a solution of 100 mg/L free chlorine, rinsed with chlorine demand free water and baked for 2 h at 200°C. Following this initial treatment, only a soaking in free chlorine and rinsing in the demand free water were performed. For all of the disinfection experiments, a 2.5% sodium hypochlorite solution (2.38 g/L of free chlorine) was used, which is suitable for the disinfection and treatment of drinking water, in accordance with the Brazilian regulations (Ministry of Health 3.1862.0001 MS). A chlorine stock solution of 100 mg/L was prepared, and a dilution in the BDF of this stock solution was performed to achieve the initial concentration of free chlorine to be used in the disinfection experiments (0.2 mg/L and 0.5 mg/L).

Experimental design for disinfection

The viral inactivation was performed with 0.2 mg/L and 0.5 mg/L of the free chlorine because the minimum concentration required by the MH 2.914/2011 is 0.2 mg/L [22]. The temperatures selected were 15°C and 20°C, for 0.2 mg/L and 0.5 mg/L of the free chlorine, except for the experiments with the BDF buffer, which were only performed at 20°C. The volume used in the experiment was 10 mL to be able to observe a 4log10 decay (100 μL viral inoculums - 9 x 107 FFU), although the same experimental conditions were also performed with 40 mL (400 μL viral inoculums – 3.6 x 108 FFU) (Table 4). All of the experiments were performed in duplicate.

Table 4 Experimental design for disinfection

Free chlorine decay in water samples

All of the experiments that evaluated the free chlorine decay were performed with 50 mL, because the technique (DPD method - HANNA Instruments (HI 95711)) used requires aliquots of 10 mL per analysis point.

In the glassware chlorine-free beakers, 50 mL of the LP, MQ and BDF buffer (pH 6.9 and 8.0) with 0.2 mg/L and 0.5 mg/L of the free chlorine were stirred at 20°C, and the free chlorine concentration was determined at a minimum at the beginning (time 0 s) and at the end of the disinfection time by the DPD method, using the HANNA Instruments (HI 95711).

Free chlorine decay in water samples with virus stock

For this assay, the same procedure was performed as described in section 2.4.4.1; however, this time with the addition of 500 μL of the purified virus stock.

Positive controls

In the glassware chlorine-free beakers, 10 mL of the LP, MQ and BDF buffer (pH 6.9 and 8.0) with 100 μL of the purified virus stock were stirred at 20°C. Four-hundred microliter aliquots were taken at the selected time points (0 s, 30 min and 60 min), kept on ice until the last time points were taken and analyzed by fluorescence microscopy and qPCR for the presence of viruses and the viability tests.

Viral inactivation by free chlorine

In the glassware chlorine-free beakers, 10 mL of the LP, MQ and BDF buffer (pH 6.9 and 8.0) with 100 μL of the purified virus stock with 0.2 mg/L and 0.5 mg/L of the free chlorine were stirred at 15°C and 20°C. Four-hundred microliter aliquots were taken, and the residual free chlorine was immediately quenched by placing the samples into collection tubes containing a sterile 10% sodium thiosulfate solution. The samples were kept on ice until the last time point was taken and analyzed by fluorescence microscopy and qPCR for the presence of viruses and the viability.

The same protocol was repeated using 40 mL of the water matrix and 400 μL of the purified virus to certify that the results obtained using minor water volumes (10 mL) do not exhibit any significant difference when compared with larger volumes, as used by some authors in the literature [3,5,17].

Evaluation of viral inactivation by cell culture methods

Cytotoxicity tests

The cytotoxicity tests were performed to evaluate the potential toxicity caused by the LP and MQ samples in the HEK 293A cells to be used during the disinfection studies. The HEK 293A cell monolayers (1.87 x 105 cells/well) were propagated in 24-well plates (TPP, Switzerland) for 24 h at 37°C in 5% CO2. The growth medium was discarded, and an inoculum of 100 μL/well of the pure or diluted samples (1:2, 1:4, 1:8, or 1:16) was prepared in serum-free culture medium (DMEM 1X, 1% PSA - 10 U/mL penicillin, 10 μg/mL streptomycin, 2 ng/mL amphotericin B) and adsorbed into the cells. After 1 h of incubation at 37°C in 5% CO2, 650 μL of the maintenance medium (DMEM 1X, containing 2% FBS, 1% HEPES, and 1% PSA) was added. After 24 h, the cell monolayers were observed under an inverted light microscope. These cells were fixed and stained with 0.1% crystal violet to establish a first non-cytotoxic dilution for use in further viral infectivity assays.

Cytotoxicity tests of the t-LP, t-MQ, n-LP and n-MQ samples were performed in the A549 cell monolayers (2.5 × 105 cells/well), as described for the HEK 293A cells, with the exception of the maintenance medium (DMEM ↑G 1X, 2% FBS and 1% PSA), and the monolayers were monitored for 7 days, until the staining.

Fluorescence Microscopy (FM)

The HEK 293A cells were grown to obtain confluent monolayers (1.5 x 105 cells/well) in a 48-well plate for 24 h at 37°C in 5% CO2. The growth medium was discarded, and 100 μL of each water dilution with 1% PSA was inoculated in duplicate. The cells were incubated for 1 h, and then 400 μL of the maintenance medium was added. After 24 h p.i., the cells were then observed under an epifluorescence microscope with UV light (Olympus). The viral titer was determined by the following formula: (average green cells counted x reciprocal dilution)/inoculum (mL). The results are shown in Focus Forming Units per milliliter (FFU/mL). Figure 1H displays an example of the infected green fluorescent cells that were counted and considered to determine the viral titer.

Evaluation of viral inactivation by molecular methods

Nucleic acid isolation and quantitative PCR (qPCR)

The extraction of the viral nucleic acid was performed using a commercial QIAmp MinElute Virus Spin Kit (Qiagen, Valencia, CA, USA), according to the manufacturer’s instructions. The nucleic acid was eluted in 60 μL of the elution buffer and stored at −80°C until use for the real-time PCR (quantitative PCR).

For the detection of rAdV, quantitative PCR was performed, as described by Hernroth et al. 2002 [55]. The reaction contained 1:10 dilutions of each sample and the TaqMan PCR master mix (Applied Biosystems, Foster City, CA), along with the primers and TaqMan probes at a volume of 25 μL. All of the amplifications were performed in the StepOne Plus® Real-Time PCR System (Applied Biosystems). Each sample was analyzed in triplicate. For each plate, four serial dilutions of the standard were run in triplicate for each assay, and the genome copies (gc) were measured. Ultra-pure water was used as the non-template control for each assay.

Kinetic modeling and statistical analysis

The statistical analyses were performed using GraphPad Prism version 5.0 (USA). Student’s t test was performed, and all significant differences are quoted for P < 0.05. The data were previously confirmed for a normal distribution fitting.

The chlorine decay constant (k’) for each experiment was calculated using Microsoft Excel 2007, according to the following equation:

$$ \mathrm{C}\left(\mathrm{t}\right)={\mathrm{C}}_0\ \exp \left(-k't\right) $$

where C(t) and C0 is the concentration of the free residual chlorine (mg/L) at time t and at time 0, respectively, and k’ is the first-order decay rate constant (min−1).

The values of the viral inactivation observed by fluorescence microscopy (FFU/mL) were subjected to the previously described Chick-Watson model to predict the contact time:

$$ \mathrm{L}\mathrm{n}\ N/{N}_0= - \mathrm{k}/\mathrm{k}'\mathrm{n}\ \left({{\mathrm{C}}_0}^{\mathrm{n}}\hbox{--} {{\mathrm{C}}_{\mathrm{t}}}^{\mathrm{n}}\right) $$

where Ln N/N 0 is the natural logarithm of the survival rate (concentration of viable virus at time t divided by the concentration at time 0), k is the inactivation constant rate and n is the coefficient of dilution. The K’ value of 0.0001 was adopted when the decay of the disinfectant was considered negligible [3], and the n value was considered 1 [63].

The Ct values (mg/L × min) predicted for the viral inactivation were determined by multiplying the time (min) and the concentration of free chlorine (Ct n) at each time interval that were calculated by the Chick-Watson model when an approximate 2log10, 3log10, and 4log10 inactivation occurred.

References

  1. Bosch A, Guix S, Sano D, Pinto RM. New tools for the study and direct surveillance of viral pathogens in water. Curr Opin Biotechnol. 2008;19:295–301.

    Article  CAS  PubMed  Google Scholar 

  2. Sobsey MD, Fuji T, Hall RM. Inactivation of cell-associated and dispersed hepatitis A virus in water. J Am Water Works Assoc. 1991;83:64–7.

    CAS  Google Scholar 

  3. Thurston-Enriquez JA, Haas CN, Jacangelo J, Gerba CP. Chlorine inactivation of adenovirus type 40 and feline calicivirus. Appl Environ Microbiol. 2003;69:3979–85.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  4. USEPA – United States Environmental Protection Agency. Guidance manual for compliance with the filtration and disinfection requirements for public water systems using surface water sources. Washington, DC: United States Environmental Protection Agency; 1991.

    Google Scholar 

  5. Kahler AM, Cromeans TL, Roberts JM, Hill VR. Effects of source water quality on chlorine inactivation of adenovirus, coxsackievirus, echovirus, and murine norovirus. Appl Environ Microbiol. 2010;76:5159–64.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  6. Fong TT, Lipp EK. Enteric viruses of human and animals in aquatic environments: health risks, detection, and potential water quality assessment tools. Microbiol Mol Biol Rev. 2005;69:357–71.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  7. King AMQ, Adams MJ, Carstens EB, Lefkowitz EJ. Virus taxonomy: classification and nomenclature of viruses. Ninth report of the international committee on taxonomy of viruses. San Diego: Elsevier, Academic Press; 2012.

    Google Scholar 

  8. USEPA – United States Environmental Protection Agency. Final contaminant candidate list 3 microbes: PCCL to CCL process. Washington, DC: United States Environmental Protection Agency; 2009.

    Google Scholar 

  9. Choi S, Jiang SC. Real-time PCR quantification of human adenoviruses in urban rivers indicates genome prevalence but low infectivity. Appl Environ Microbiol. 2005;71:7426–33.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  10. Albinana-Gimenez N, Miagostovich MP, Calgua B, Huguet JM, Matia L, Girones R. Analysis of adenoviruses and polyomaviruses quantified by qPCR as indicators of water quality in source and drinking-water treatment plants. Water Res. 2009;43:2011–9.

    Article  CAS  PubMed  Google Scholar 

  11. Dong Y, Kim J, Lewis GD. Evaluation of methodology for detection of human adenoviruses in wastewater, drinking water, stream water and recreational waters. J Appl Microbiol. 2010;108:800–9.

    Article  CAS  PubMed  Google Scholar 

  12. Wyn-jones AP, Carducci A, Cook N, D’Agostino M, Divizia M, Fleischer J, et al. Surveillance of adenoviruses and noroviruses in European recreational waters. Water Res. 2011;45:1025–38.

    Article  CAS  PubMed  Google Scholar 

  13. Fongaro G, Nascimento MA, Viancelli A, Tonetta D, Petrucio MM, Barardi CRM. Surveillance of human viral contamination and physicochemical profiles in a surface water lagoon. Water Sci Technol. 2012;66:2682–7.

    Article  CAS  PubMed  Google Scholar 

  14. Garcia LAT, Viancelli A, Rigotto C, Pilotto MR, Esteves PA, Kunz A, et al. Surveillance of human and swine adenovirus, human norovirus and swine circovirus in water samples in Santa Catarina, Brazil. J Water Health. 2012;10:445–52.

    Article  CAS  PubMed  Google Scholar 

  15. Ye XY, Ming X, Zhang YL, Xiao WQ, Huang XN, Cao YG, et al. Real-time PCR detection of enteric viruses in source water and treated drinking water in Wuhan, China. Curr Microbiol. 2012;65:244–53.

    Article  CAS  PubMed  Google Scholar 

  16. Page MA, Shisler JL, Mariñas BJ. Kinetics of adenovirus type 2 inactivation with free chlorine. Water Res. 2009;43:2916–26.

    Article  CAS  PubMed  Google Scholar 

  17. Cromeans TL, Kahler AM, Hill VR. Inactivation of adenoviruses, enteroviruses, and murine norovirus in water by free chlorine and monochloramine. Appl Environ Microbiol. 2010;76:1028–33.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  18. Corrêa AA, Carratala A, Barardi CRM, Calvo M, Girones R, Bofill-Mas S. Comparative inactivation of murine norovirus, human adenovirus, and human JC polyomavirus by chlorine in seawater. Appl Environ Microbiol. 2012;78:6450–7.

    Article  Google Scholar 

  19. Francy DS, Stelzer EA, Bushon RN, Brady AMG, Williston AG, Riddell KR, et al. Comparative effectiveness of membrane bioreactors, conventional secondary treatment, and chlorine and UV disinfection to remove microorganisms from municipal wastewaters. Water Res. 2012;46:4164–78.

    Article  CAS  PubMed  Google Scholar 

  20. Luo J, Deng ZL, Luo X, Tang N, Song WX, Chen J, et al. A protocol for rapid generation of recombinant adenoviruses using the AdEasy system. Nat Protoc. 2007;2:1236–47.

    Article  CAS  PubMed  Google Scholar 

  21. Graham FL, Smiley J, Russell WC, Nairn R. Characteristics of a human cell line transformed by DNA from human adenovirus type 5. J Gen Virol. 1977;36:59–72.

    Article  CAS  PubMed  Google Scholar 

  22. ANVISA. Agência Nacional de Vigilância Sanitária: Ordinance n° 2914/MH of December 12. Brasília: Ministry of Health; 2011.

    Google Scholar 

  23. Fontes MLS, Tonetta D, Dalpaz L, Antônio RV, Petrucio MM. Dynamics of planktonic prokaryotes and dissolved carbon in a subtropical coastal lake. Front Microbiol. 2013;4:71–9.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  24. Chigor VN, Sibanda T, Okoh AI. Assessment of the risks for human health of adenoviruses, hepatitis a virus, rotaviruses and enteroviruses in the buffalo river and three source water dams in the eastern cape. Food Environ Virol. 2014;6:87–98.

    Article  CAS  PubMed  Google Scholar 

  25. Fewtrell L, Kay D, Watkins J, Davies C, Francis C. The microbiology of urban UK floodwaters and a quantitative microbial risk assessment of flooding and gastrointestinal illness. J Flood Risk Manage. 2011;4:77–87.

    Article  Google Scholar 

  26. Girones R, Ferrús MA, Alonso JL, Rodriguez-Manzano J, Calgua B, Corrêa AA, et al. Molecular detection of pathogens in water - the pros and cons of molecular techniques. Water Res. 2010;44:4325–39.

    Article  CAS  PubMed  Google Scholar 

  27. Kundu A, McBride G, Wuertz S. Adenovirus-associated health risks for recreational activities in a multi-use coastal watershed based on site-specific quantitative microbial risk assessment. Water Res. 2013;47:6309–25.

    Article  CAS  PubMed  Google Scholar 

  28. Zhang CM, Wang XC. Distribution of enteric pathogens in wastewater secondary effluent and safety analysis for urban water reuse. Hum Ecol Risk Assess. 2014;20:797–806.

    Article  CAS  Google Scholar 

  29. Prütz WA. Reactions of hypochlorous acid with biological substrates Are activated catalytically by tertiary amines. Arch Biochem Biophys. 1998;357:265–73.

    Article  PubMed  Google Scholar 

  30. Page MA, Shisler JL, Marinãs BJ. Mechanistic aspects of adenovirus serotype 2 inactivation with free chlorine. Appl Environ Microbiol. 2010;76:2946–54.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  31. Cromeans TL, Lu X, Erdman DD, Humphrey CD, Hill VR. Development of a plaque assay for adenoviruses 40 and 41. J Virol Methods. 2008;151:140–5.

    Article  CAS  PubMed  Google Scholar 

  32. Mazzola PG, Ishii M, Chau E, Cholewa O, Penna TC. Stability of Green Fluorescent Protein (GFP) in chlorine solutions of varying pH. Biotechnol Progr. 2006;22:1702–7.

    Article  CAS  Google Scholar 

  33. Webb JS, Barratt SR, Sabev H, Nixon M, Eastwood IM, Greenhalgh M, et al. Green fluorescent protein as a novel indicator of antimicrobial susceptibility in Aureobasidium pullulans. Appl EnViron Microbiol. 2001;67:5614–20.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  34. Casey WM, Nguyen NT. Use of the green fluorescent protein to rapidly assess viability of Escherichia coli in preserved solutions. PDA J Pharm Sci Tech. 1995;50:352–5.

    Google Scholar 

  35. AWWA - American Water Works Association. Water chlorination/chloramination practices and principles, Manual of water supply practices – M20. Denver, Colorado: American Water Works Association; 2006.

    Google Scholar 

  36. Krauskopf BK. Introduction to geochemistry. New York: McGraw- Hill; 1983.

    Google Scholar 

  37. Pettry DE, Switzer RE. Heavy metal concentration in selected soils and parent materials in Mississippi, Bulletin 998. MSU: Meridian; 1993.

    Google Scholar 

  38. Andrade LN, Leite MGP, Bacellar LAP. Influence of the geology in the chemical signature of water and soils from the Itacolomi State Park, Minas Gerais. R Esc Minas. 2009;62:147–54.

    Article  Google Scholar 

  39. Howland RJ, Tappin AD, Uncles RJ, Plummer DH, Bloomer NJ. Distributions and seasonal variability of pH and alkalinity in the Tweed Estuary, UK. Sci Total Environ. 2000;251–252:125–38.

    Article  PubMed  Google Scholar 

  40. Morris AW, Mantoura RFC, Bale AJ, Howland RJM. Very low salinity regions of estuaries: important sites for chemical and biological reactions. Nature. 1978;274:678–80.

    Article  CAS  Google Scholar 

  41. Wang X, Cai Q, Ye L, Qu X. Evaluation of spatial and temporal variation in stream water quality by multivariate statistical techniques: A case study of the Xiangxi River basin, China. Quatern Int. 2012;282:137–44.

    Article  Google Scholar 

  42. Belevantsev VI, Ryzhikh AP, Smolyakov BS. Diurnal and vertical variability of pH, [O2], and E h in the Novosibirsk water reservoir. Russ Geol Geophys. 2008;49:673–81.

    Article  Google Scholar 

  43. Palma P, Ledo L, Soares S, Barbosa IR, Alvarenga P. Spatial and temporal variability of the water and sediments quality in the Alqueva reservoir (Guadiana Basin; southern Portugal). Sci Total Environ. 2014;470–471:780–90.

    Article  PubMed  Google Scholar 

  44. Manahan SE. Environmental chemistry. 9th ed. Boca Raton, Florida: Taylor & Francis Group; 2010.

    Google Scholar 

  45. March JG, Gual M, Ramonell J. A kinetic model for chlorine consumption in greywater. Desalination. 2005;181:267–73.

    Article  CAS  Google Scholar 

  46. Winward GP, Avery LM, Stephenson T, Jefferson B. Chlorine disinfection of grey water for reuse: effect of organics and particles. Water Res. 2008;42:483–91.

    Article  CAS  PubMed  Google Scholar 

  47. Daskalakis V, Charalambous F, Panagiotou F, Nearchou I. Effects of surface-active organic matter on carbon dioxide nucleation in atmospheric wet aerosols: a molecular dynamics study. Phys Chem Chem Phys. 2014;16:23723–34.

    Article  CAS  PubMed  Google Scholar 

  48. Winter J, Ilbert M, Graf PCF, Ozcelick D, Jakob U. Bleach activates a redox-regulated chaperone by oxidative protein unfolding. Cell. 2008;135:691–701.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  49. Pattison DI, Davies MJ. Absolute rate constants for the reaction of hypochlorous acid with protein side chains and peptide bonds. Chem Res Toxicol. 2001;14:1453–64.

    Article  CAS  PubMed  Google Scholar 

  50. Ma JF, Straub TM, Pepper IL, Gerba CP. Cell culture and PCR determination of poliovirus inactivation by disinfectants. Appl Environ Microbiol. 1994;60:4203–6.

    PubMed Central  CAS  PubMed  Google Scholar 

  51. Kitajima M, Tohya Y, Matsubara K, Haramoto E, Utagawa E, Katayama H. Chlorine inactivation of human norovirus, murine norovirus and poliovirus in drinking water. Lett Appl Microbiol. 2010;51:119–21.

    CAS  PubMed  Google Scholar 

  52. Lim MY, Kim JM, Ko G. Disinfection kinetics of murine norovirus using chlorine and chlorine dioxide. Water Res. 2010;44:3243–51.

    Article  CAS  PubMed  Google Scholar 

  53. Shin GA, Sobsey MD. Inactivation of norovirus by chlorine disinfection of water. Water Res. 2008;42:4562–8.

    Article  CAS  PubMed  Google Scholar 

  54. Xue B, Jin M, Yang D, Guo X, Chen Z, Shen Z, et al. Effects of chlorine and chlorine dioxide on human rotavirus infectivity and genome stability. Water Res. 2013;47:3329–38.

    Article  CAS  PubMed  Google Scholar 

  55. Hernroth BE, Conden-Hansson AC, Rehnstam-Holm AS, Girones R, Allard AK. Environmental factors influencing human viral pathogens and their potential indicator organisms in the blue mussel, Mytilus edulis: the first Scandinavian report. Appl Environ Microbiol. 2002;68:4523–33.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  56. Helmi K, Skraber S, Gantzer C, Willame R, Hoffmann L, Cauchie HM. Interactions of Cryptosporidium parvum, Giardia lamblia, vaccinal poliovirus type 1, and bacteriophages ϕ174 and MS2 with a drinking water biofilm and a wastewater biofilm. Appl Environ Microbiol. 2008;74:2079–88.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  57. Szewzyk U, Szewzyk R, Manz W, Schleifer KH. Microbiological safety of drinking water. Annu Rev Microbiol. 2000;54:81–127.

    Article  CAS  PubMed  Google Scholar 

  58. Daniel LA. Rede cooperativa de pesquisas: Métodos alternativos de desinfecção da água, Prosab. Rio de Janeiro: ABES; 2001.

    Google Scholar 

  59. Calgua B, Fumian T, Rusiñol M, Rodriguez-Manzano J, Mbayed VA, Bofill-Mas S, et al. Detection and quantification of classic and emerging viruses by skimmed-milk flocculation and PCR in river water from two geographical areas. Water Res. 2013;47:2797–810.

    Article  CAS  PubMed  Google Scholar 

  60. Golterman HL, Clymo RS, Ohnstad MAM. Methods for physical and chemical analysis of freshwater. Oxford: Blackwell Scientific Publications; 1978.

    Google Scholar 

  61. Mackereth FJH, Heron J, Talling JF. Water Analysis: some revised methods for limnologists, Freshwater biological association, scientific publication. Kendal: Titus Wilson & Sons Ltda; 1978.

    Google Scholar 

  62. Koroleff F. Determination of nutrients. In: Grasshoff K, editor. Methods of Sea water analysis. 1st ed. Weinhein: Verlag Chemie; 1976. p. 117–81.

    Google Scholar 

  63. MWH - Montgomery Watson Harza. Water treatment: principles and design. Hoboken, New Jersey: John Wiley & Sons; 2005.

    Google Scholar 

Download references

Acknowledgments

Financial support for this research was provided by National Counsel of Technological and Scientific Development (CNPq) and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Célia RM Barardi.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

MAN and CRMB designed the research. MAN carried out the collection of water samples and concentration of treated water samples, physicochemical parameters and fecal contamination analysis, reagents and glassware treatments, cytotoxicity tests, disinfection assays, microscopy fluorescence and qPCR assays. MEM and MAN carried out the kinetic modeling and statistical analysis.CDS performed the plaque assay. CRMB conceived of the study, and participated in its design and coordination and helped to draft the manuscript. All authors read and approved the final manuscript.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nascimento, M.A., Magri, M.E., Schissi, C.D. et al. Recombinant adenovirus as a model to evaluate the efficiency of free chlorine disinfection in filtered water samples. Virol J 12, 30 (2015). https://doi.org/10.1186/s12985-015-0259-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12985-015-0259-7

Keywords