Skip to main content

Table 3 Pathogens used and Ct values of the duplex real-time PCR assay’s specificity

From: A duplex real-time PCR assay for the detection and quantification of avian reovirus and Mycoplasma synoviae

Pathogen Number of samples Ct values of duplex real-time PCR assay
MS ARV
NDV 1 Negative Negative
H9 subtype of AIV 1 Negative Negative
AIBV 1 Negative Negative
IBDV 1 Negative Negative
MG 1 Negative Negative
MM 1 Negative Negative
MI 1 Negative Negative
MDV 1 Negative Negative
pMD18-T-ARV 1 Negative 15.58
pMD18-T-MS 1 15.31 Negative
REV 1 Negative Negative
ALV 1 Negative Negative