Table 1 Validation of the recomLine VZV with clinically defined sera

From: A systematic approach for the identification of novel, serologically reactive recombinant Varicella-Zoster Virus (VZV) antigens

Assay

Result

Clinically defined sera

Serologically defined VZV-IgG/IgM Neg serad

  

Chickenpox

Zoster

  
  

IgG

IgM

IgG

IgM

IgG

IgM

ELISA

Pos a

5

5

18

9

0

0

 

Inc b

0

0

0

0

0

0

 

Neg c

0

0

0

9

24

24

RecomLine VZV

Pos

5

5

17

11

0

0

 

Inc

0

0

1

0

0

0

 

Neg

0

0

0

7

24

24

  1. NOTE. Data are no. of serum samples.
  2. a Pos: positive; bInc: inconclusive; cNeg: negative, d: as assayed by Siemens Enzygnost VZV IgG/IgM wcELISA.
  3. RecomLine VZV strips were considered as positive when the intensity of the ORF68 band was higher than the cut-off band control.