Skip to main content

Table 6 Evaluation of RT-LAMP amplification using mismatched sequences

From: Detection of Middle East respiratory syndrome coronavirus using reverse transcription loop-mediated isothermal amplification (RT-LAMP)

Accession

Name

   

Sensitivity (copies)

JX869059

EMC

 

15.8

Representative sequence

Nucleotide position*

Substitution

Region in primer

Sensitivity (copies)

 

England2

28862

C to T

F3

7.3

KJ782550

Greece-Saudi Arabia_2014

28862

C to T

F3

15.8

  

28880

T to C

FIP (F2)

 

KJ650098

Camel/Qatar_2_2014

28880

T to C

FIP (F2)

34.1

KJ156905

Riyadh_7b_2013

28958

T to C

BIP (B1)

15.8

KF917527

Jeddah-Camel-1

29018

G to T

BIP (B2)

73.4

KJ477102

NRCE-HKU205

28982

C to T

LB

39.7

KF961221

Qatar3

28996

C to T

LB

7.3

  1. *Based on EMC isolate (JX869059.2).