Table 5 Comparison of the consistency of the Well oral anti-HCV test conducted by researchers versus participants

From: Evaluation of a new point-of-care oral anti-HCV test for screening of hepatitis C virus infection

Well oral anti-HCV assay, self-testing

Well anti-HCV assay, researcher administered (n = 199)

 

Center 1 (n = 65)

Center 2 (n = 66)

Center 3 (n = 68)

Centers 1–3 (n = 199)

Total

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

 

Positive, n

24

1

28

0

23

1

75

2

77

Negative, n

0

40

0

38

0

44

0

122

122

Total

24

41

28

38

23

45

75

124

199

Consistencyd (%) (95% CI)

98.46(91.00,100.00)

100.00(93.41,100.00)

98.53(91.37,100.00)

98.99(96.17,99.96)

Kappa valued

0.967

1.000

0.967

0.979

  1. Note: dConsistency and Kappa value were calculated according to the results of the Well oral anti-HCV test conducted by researchers. Consistency means the overall coincidence rate between the Well oral anti-HCV test conducted by researchers and conducted by participants. n Number, 95%CI x95% confidence interval