Skip to main content

Table 1 Virus isolation from the inactivated NiV using a protocol shown in Fig. 1

From: Effective inactivation of Nipah virus in serum samples for safe processing in low-containment laboratories

  No treatment UV (30 min) and heating (56 °C for 30 min) in combination
In 90% human serum In GM In 90% serum In GM
7 dpi  +   +   −   − 
In blind passages NT NT  −   − 
  1.  + CPEs positive
  2.  − CPEs negative
  3. GM Growth medium (DMEM-10FBS), dpi days post-infection, NT not tested
\