Skip to main content

Table 2 Evaluation of 2nd-generation CHIKV E1 detection RDT version B in clinical samples

From: Promising application of monoclonal antibody against chikungunya virus E1-antigen across genotypes in immunochromatographic rapid diagnostic tests

IgG/IgM

PCR

IC RDT

Sensitivity

Specificity

OAA

(+)

(−)

(−)

(+)

4

1

80.0

 

92.5

(−)

2

33

 

94.3

 

(+)

(+)

7

14

33.3

 

47.5

(−)

7

12

 

63.2

 

Total

(+)

11

15

42.6

 

70.0

(−)

9

45

 

83.3

 
  1. IgG/IgM (−): anti-CHIKV IgM- and IgG-negative cases
  2. IgG/IgM (+): anti-CHIKV IgM- or IgG-positive cases
  3. Sensitivity: percentage of matches between results of PCR and IC RDT in PCR positive samples
  4. Specificity: percentage of matches between results of PCR and IC RDT in PCR negative samples
  5. OAA overall agreement (percentage of total matches between results of PCR and IC RDT)