Skip to main content

Advertisement

Table 1 Detection limits of HAdV 3 and HAdV 7 in singleplex and duplex RAA assays

From: Development and evaluation of recombinase-aided amplification assays incorporating competitive internal controls for detection of human adenovirus serotypes 3 and 7

Copies/reaction No. of positive samples/no. of samples tested by the RAA assay for detection of HAdV 3 and HAdV 7
Singleplex RAA Duplex RAA
HAdV 3 HAdV 7 HAdV 3 HAdV 7
1 copy/μL 6/8 2/8 2/8 0/8
101 copy/μL 8/8 8/8 8/8 4/8
102 copy/μL 8/8 8/8 8/8 8/8
103 copy/μL 8/8 8/8 8/8 8/8
104 copy/μL 8/8 8/8 8/8 8/8