Skip to main content

Advertisement

Table 1 Comparison of VNT and PRNT assays for a panel of 142 samples

From: Correction to: Combination of ELISA screening and seroneutralisation tests to expedite Zika virus seroprevalence studies

VNT PRNT50 PRNT90
Positive (titre ≥10) Negative (titre < 10) Positive (titre ≥10) Negative (titre < 10)
Positive (titre ≥40) 51 1 51 1
Negative (titre < 40) 9 81 1 89
Sensitivity of VNT (95% CI) 85% (51/60) (72.9–92.4%) 98.8% (51/52) (88.4–99.9%)
Specificity of VNT (95% CI) 98.7% (81/82) (92.4–99.9%) 98.8% (89/90) (93.1–99.9%)