Skip to main content

Table 2 Replication experiment to evaluate precision for plasma (A) and VTM (B)

From: Comparative evaluation of a laboratory-developed real-time PCR assay and RealStar® Adenovirus PCR Kit for quantitative detection of human adenovirus

Nominal (log10 copies/mL)

No. of sample tested

Mean HAdV DNA load (log10 copies/mL) Intra-assay

SD (log10 copies/mL) Intra-assay

%CV Intra-assay

Mean HAdV DNA load (log10 copies/ ml)

Inter-assay

SD (log10 copies/mL) Inter-assay

%CV Inter-assay

A

 9

3

9.12

0.01

0.05

9.12

0.01

0.07

 8

3

8.07

0.01

0.09

8.07

0.01

0.07

 7

3

6.94

0.01

0.13

6.94

0.01

0.10

 6

3

5.82

0.01

0.11

6.81

0.01

0.12

 5

3

4.80

0.02

0.38

4.80

0.02

0.33

 4

3

4.08

0.02

0.54

4.10

0.03

0.71

 3

3

3.16

0.05

1.50

3.15

0.10

3.21

 2.60

3

2.85

0.02

0.63

2.90

0.07

2.42

B

       

 9

3

9.11

0.01

0.05

9.12

0.02

0.17

 8

3

8.03

0.01

0.10

8.02

0.01

0.17

 7

3

6.93

0.01

0.22

6.92

0.02

0.26

 6

3

5.87

0.01

0.19

5.88

0.02

0.26

 5

3

4.91

0.02

0.37

4.91

0.01

0.25

 4

3

4.05

0.05

1.27

4.05

0.04

1.00

 3

3

3.10

0.06

1.84

3.10

0.04

1.44

 2.94

3

2.92

0.02

0.57

2.92

0.06

2.11