Table 2 Comparison of hands-on and processing time of four extraction methods evaluated in this study. The time for each operator step corresponds to twelve samples

From: Development of molecular confirmation tools for swift and easy rabies diagnostics

 

Required time (minutes)

Operator step

TRIzol & RNeasy

SpeedXtract

EZ1

KF Duo

filling of reagents

15

10

mix sample + lysis buffer

5

5

5

5

incubation

10

5

load instrument

5

1

extraction/instrument run

30

10

16

8

total hands-on time

35

15

25

16

total processing time

45

20

41

24