Skip to main content

Table 5 Discordant results of custom and FTD assays

From: Evaluation of custom multiplex real - time RT - PCR in comparison to fast - track diagnostics respiratory 21 pathogens kit for detection of multiple respiratory viruses

Custom assay

FTD assay

Number of samples

RSV A/B

NEGATIVE

07

HBoV + RSV A/B

HBoV

02

HRV + RSVA/B

HRV

02

EV + RSV A/B

EV

01

HMPVA/B + RSV A/B + Flu B

HMPVA/B + Flu B

01

Influenza A(H1N1)pdm09 + RSVA/B + HBoV

Influenza A(H1N1)pdm09 + HBoV

01

HMPVA/B + RSV A/B

HMPVA/B

01

Flu B + RSV A/B

Flu B

01

HPIV-3 + RSV A/B

HPIV-3

01

HPIV-3 + HRV

HRV

01

HBoV + HPIV-3

HBoV

01

aHPIV-4 + HRV

aHPIV-3 + HRV

01

EV

NEGATIVE

02

NEGATIVE

EV

01

HBoV

HBoV + EV

01

HCoV OC43

HCoV OC43+ HCoV HKU1

01

HRV + HAdV

HRV

01

HPIV-2 + Flu B

HPIV-2

01

HPIV-3

NEGATIVE

01

NEGATIVE

HPIV-4

01

NEGATIVE

HCoV NL63

01

HPIV-3

HPIV-3 + HMPVA/B

01

Influenza A(H1N1)pdm09 + EV

Influenza A(H1N1)pdm09

01

HRV + RSVA/B

HRV

01

NEGATIVE

RSV A/B

01

HRV + EV

HRV

01

  1. aThis sample is counted as variation of co-infection on both the sides