Skip to main content

Table 1 Detection limit comparison between ELISA-array and traditional ELISA

From: Development of an ELISA-array for simultaneous detection of five encephalitis viruses

 

ELISA-array (TCID50/ml)

Traditional ELISA(TCID50/ml)

JEV

1.5 × 104

6 × 104

TBEV

8 × 103

8 × 104

DV2

6.25 × 104

1.25 × 105

EEEV

8 × 104

1.6 × 105

DV4

6 × 104

6 × 105

SV

2.5 × 106

1.25 × 106