Skip to main content

Table 3 Limit of detection of the duplex real-time PCR assay

From: Development of a new duplex real-time polymerase chain reaction assay for hepatitis B viral DNA detection

HBV load (IU/ml) Positive results/total tested Positive results (%)
105 24/24 100
104 24/24 100
103 24/24 100
102 24/24 100
50 24/24 100
25 22/24 91.6
10 12/24 50.0
5 5/24 20.8